Price:
€
46.83
Ship From:
Dispatch:Usually will be shipped inbusiness dayshours
Loading...
Ship to
1. AC CURRENT
Range
|
Resolution |
Accuracy |
6A |
0.001A |
±(2.5% + 8) |
60A |
0.01A |
|
600A |
1A |
- maximum/ input current:1000A AC
- Frequency range:50Hz
2. DC CURRENT
Range
|
Resolution |
Accuracy |
60A |
0.01A |
±(2.0% + 8) |
600A |
1A |
- maximum/ input current:600A DC
3. Surge Current
Range
|
Resolution |
Accuracy |
6A |
0.001A |
<60A as referrence ±(5% + 60) |
60A |
0.01A |
|
600A |
1A |
Integral time:100ms;range:20 ~ 600A;Frequency range:40 ~ 400Hz
4. DC Voltage
Range
|
Resolution |
Accuracy |
60mV |
0.01mV |
±(0.5% + 5) |
600mV |
0.1mV |
|
6V |
0.001V |
|
60V |
0.01V |
|
600V |
0.1V |
- Input impedance:10MΩ
-Maximum/ input voltage:600V AC (Effective value)OR 600V DC
NOTICE:
In the small voltage range, one has not received the test circuit, the instrument may be beating reading,
it'snormal, this is due to the high sensitivity of the instrument .
without detriment to the actual measurement results.
5. AC Voltage
Range
|
Resolution |
Accuracy |
6V |
0.001V |
±(0.8% + 5) |
60V |
0.01V |
|
600V |
0.1V |
- Input impedance:10MΩ
- Maximum/ input voltage:600V AC (Effective value)or 600V DC
- Frequency range:40 ~ 1000Hz
NOTICE:
In the small voltage range, one has not received the test circuit, the instrument may be beating reading,
it's normal, this is due to the high sensitivity of the instrument .
without detriment to the actual measurement results.
6. Frequency
6.1 Through the V file:
Range
|
Resolution |
Accuracy |
99.99Hz |
0.01Hz |
±(1.5% + 5) |
999.9Hz |
0.1Hz |
|
9.999kHz |
0.001kHz |
- Range:10Hz ~ 10kHz
- Input voltage range:≥ 20mV AC(Effective value)(With the increase of the measured frequency, the input voltage should be increased)
- Input impedance:10MΩ
- Maximum/ input voltage:600V AC(Effective value)
6.2 Through HZ/DUTY File:
Range
|
Resolution |
Accuracy |
9.999Hz |
0.001Hz |
±(0.3% + 5) |
99.99Hz |
0.01Hz |
|
999.9Hz |
0.1Hz |
|
9.999kHz |
0.001kHz |
|
99.99KHZ |
0.01kHZ |
|
999.9KHZ |
0.1KHZ |
|
9.999MHZ |
0.001MHZ |
- Overload protection:250V DC or AC(Effective value)
- Input voltage range:≥ 2V(With the increase of the measured frequency, the input voltage should be increased)
7. Duty Ratio
Range
|
Resolution |
Accuracy |
0.1 – 99.9% |
0.1% |
± 3.0% |
7.1 Through A file(From the clamp head):
- Frequency response:10 ~ 1kHz
- Input current range:≥20A AC(Effective value)
- Maximum/ input current:AC 1000A
7.2 Through the V file:
- Frequency response:10 ~ 10kHz
- Input voltage range:≥ 60mV AC
- Input impedance:10MΩ
- Maximum /input voltage:750V AC(Effective value)
7.3 Through HZ/DUTY file:
- Frequency response:10 ~ 10MHz
- Input voltage range:≥ 2V AC(Effective value)(With the increase of the measured frequency, the input voltage should be increased)
- Maximum /input voltage:250V AC(Effective value)
8. Resistance
Range
|
Resolution |
Accuracy |
600Ω |
0.1Ω |
±(0.8% + 3) |
6kΩ |
0.001kΩ |
|
60kΩ |
0.01kΩ |
|
600kΩ |
0.1kΩ |
|
6MΩ |
0.001MW |
±(1.2% + 3) |
60MW |
0.1MΩ |
- Open-circuit voltage:About 0.4V
- Overload protection:250V DC OR AC(Effective value)
9. Continuity Test
Range
|
Resolution |
Function |
0. 1Ω |
If the measured line resistance is less than 50Ω, enclosing the instrument may sound a buzzer |
- Overload protection:250V DC or AC(Effective value)
10. Capacitance
Range
|
Resolution |
Accuracy |
9.999nF |
0.001nF |
±(3.0% + 5) |
99.99nF |
0.01nF |
|
999.9nF |
0.1nF |
|
9.999mF |
0.001mF |
|
99.99mF |
0.01mF |
|
999.9mF |
0.1mF |
|
9.999mF |
0.001mF |
±(5.0% + 5) |
99.99mF |
0.01mF |
- Overload protection:250V DC or AC(Effective value)
11. Diode Test
Range
|
Resolution |
Function |
0.001V |
Show the approximate diode forward voltage value |
- positive DC current 1mA
- Reverse DC voltage 3.0V
- Overload protection:250V DC or AC(Effective value)