Favorites
  • Certified Hantek DSO5102P Digital Storage Oscilloscope 2CH 100MHz 1Gs 7
Certified Hantek DSO5102P Digital Storage Oscilloscope 2CH 100MHz 1Gs 7" TFT 8-bit 4nS/div-80S/div

Certified Hantek DSO5102P Digital Storage Oscilloscope 2CH 100MHz 1Gs 7" TFT 8-bit 4nS/div-80S/div

2CH 100MHz 1Gs 7" TFT 8-bit 4nS/div-80S/div

4.5
(2 Customer Reviews)
| Brand:hantek (0)

Share:

Ship From:

  • China Warehouse

Dispatch:Usually will be shipped inbusiness dayshours

Shipping: Loading...
Sorry, it seems that there are no available shipping methods for your location.Please contact us for further assistance.

Loading...

Ship to

Anguilla
: china

plug_type:

QTY:

Wholesale Inquiry

Special discount has ended

Please note each user for only 1 item(s)

Buyer Protection

  • Full Refund If you don't receive your order
  • Full or Partial Refund , If the item is not as described Learn more >
This digital oscilloscope probe is professional oscillometer and very practical for testing the electric current and voltage. The oscilloscope can put the invisible to the naked eye the electrical signals into visible image, convenient for people to study the changing process of various electrical phenomena.

Features:
100MHz bandwidth.
1GSa/s real time sample rate.
Large (7.0-inch) color display,WVGA(800x480).
Record length up to 40K.
Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
USB host and device connectivity, standard.
Multiple automatic measurements.
Four math functions, including FFTs standard.
Provides software for PC real-time analysis.
VGA Optional.

Note:
Hantek DSO5102P Digital Oscilloscope is for 3 years Warranty!
Please read the instruction manual data CD carefully to avoid injury and prevent damage to this product.

Specifications:
Material: ABS
Bandwidth: 70MHz / 100MHz (Optional)
Plug Type: US / EU (Optional)
Oscilloscope Probe Model: PP-80/150/200
Length of the Powerline: Approx. 150cm / 59.1in 
Length of the USB Line: Approx. 107cm / 42.1in 
Length of the Probe Line: Approx. 130cm / 51.2in 
Size of the Oscilloscope Body: Approx. 31.5 * 13 * 15.2cm / 12.4 * 5.1 * 6.0in (L * W * H)
Oscilloscope Weight: 2.00kg/ 4.4lb
Package Size: Approx. 38.5 * 19.5 * 24cm / 15.1 * 7.7 * 9.4in
Package Weight: 2.87kg/ 6.3lb  (2867.5g/101.1oz)
Model DSO5102P       
Acquisition
Sample Rate Real-Time Sample: 1GS/s
Acquisition Modes
Normal Normal data only
Peak Detect High-frequency and randon glith capture
Average Wavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs Coupling AC, DC, GND
Inputs Impendance 1MΩ±2% ‖20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal System
Sample Rate Range 500MS/s--1GS/s
Waveform Interpolation (sin x)/x
Record Length 40K
SEC/DIV Range 4ns/div to 40s/div
Sample Rate and
Delay Time Accuracy
±50ppm(at over any ≥1ms time interval)
Position Range 20ns/div to 80us/div; (-8div x s/div) to 40ms;
200us/div to 40s/div; (-8div x s/div) to 400s
Delta Time Measurement Accuracy 
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Position Range 2mV/div to 10V/div
Bandwidth 100MHz
Rise Time at BNC( typical) 3.5ns
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled 2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math +, -, *, /, FFT
FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit 20MHz
Low Frequency Response (-3db) ≤10Hz at BNC
DC Gain Accuracy ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, 
Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; 
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, 
Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT): 
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):       
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;       
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz 
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level Range CH1/CH2: ±8 divisions from center of screen; 
EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) Operates with input signals ≥50Hz
Video Trigger
Video Trigger Type  CH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5: 2V
Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger Mode Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~ 10s
Slope Trigger
Slope Trigger Mode Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~ 10s
Overtime Trigger
Over Time Mode Rising edge or Falling edge
Time Range 20ns ~ 10s
Alternative Trigger
Trigger on CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor Measurement Voltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT)
Auto Measuerment Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Display
Display Type 7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution 800 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output
Output Voltage( typical) About 5Vpp into ≥1MΩ load
Frequency(typical) 1kHz
Power Supply
Supply Voltage 100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ
120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ
Power Consumption <30W
Fuse 2A, T rating, 250V
Environmental
Temperature Operating: 32℉ to 122℉ (0℃ to 50℃);
Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃)
Cooling Method Convection
Humidity +104℉ or below (+40℃ or below): ≤90% relative humidity;
106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity
Altitude Operating: Below 3,000m (10,000 feet);
Nonoperaring: Below 15,000m(50,000 feet)
Mechanical
Size Length 315mm, Width 130mm, Height 152mm
Weight 2.9KG(with Packing);  2.00KG(without Packing

Package List:
1 * Digital Storage Oscilloscope
2 * Oscilloscope Probe
1 * Oscilloscope Powerline
1 * Hantek Data CD
1 * USB Line
Customer Reviews

Average Rating:

4.5

based on 2 Customer Reviews

  • 5 stars
    50%
  • 4 stars
    50%
  • 3 stars
  • 2 stars
  • 1 stars

Share your thoughts with other customers and get Cafago Points, the first 5 reviews get DOUBLE Cafago Points!

Write a Customer Review
  • By a***2

    May 16, 2018

    Quick service, awesome pricing

    Is this helpful? (0) (0)

  • By j***6

    April 25, 2018

    good transaction

    Is this helpful? (0) (0)

Top Sellers More

Please activate your account and then to buy,We will resend the activation email to help you complete your registration.

cafago use cookies to give you the best shopping experience. If you continue to use our services or create a new account, we will assume that you agree to our  Privacy Policy.
Click here to reject the cookies